Product Category

Screwed Glands Lab Test Apparatus

To determine the torque strength of the screwed glands,in accordance with the IEC60598-1 clause 4.12.5.

Screwed Glands Lab Test Apparatus


Product details: Model ZLT-LWM1.


To determine the torque strength of the screwed glandsin accordance with the IEC60598-1 clause 4.12.5.

Screwed glands shall be fitted with a cylindrical metal rod having a diameter equal to the nearest whole number of millimeter below the internal diameter of the packing. The glands shall then be tightened by means of a suitable spanner, the moment shown in following table being applied to the spanner for 1 min.  


Table Torque tests on glands

    Diameter of test rod

         (mm) 

                      Moment

 

Metal glands

(Nm)

Moulded plastic glands      (Nm)

Up to and  7

6,25

2,5

Over 7 up to  14

6,25

3,25

Over 14 up to  20

7,50

5

Over 20

10

7,50


Standard Outfit:

1 set of stainless steel test rods 4~40mm,

1 set of weights,15 N-20 N-25 N-30 N-40 N,

1 cylinder, diameter 250 mm.

Inquiry